12 Document No 552625 Iss. 6 June 2005 1
ELECTRICAL INSTALLATION
External Bell
All bells must be approved for connection to the telephone netwrk. They
are of the low frequency A.C. ~pe (15Hz-25Hz). D.C. versions must NOT
be used. Connect to terminals 2 and 4 of the tag block. Ensure that DIP
switch SW18 3 is set to '3 (ON)' enabling the internal bell capacitor if a
master socket is NOT used.
Call Restriction Timeout (used when 'CLEAR' key is not fitted)
If this facility is enabled (SW18 -1 set to 'OFF') then each call will be time
restricted to approximately 1 minute, in one of two ways, set by SW18 - 2.
1. Fixed - (SW18- 2 set to 'OFF') the 1 minute starts from the last press
(and release) of the 'PRESS TO CALL' key or the service required.
2. Auto - (SW18 - 2 set to 'ON') the 1 minute starts from the end the last
incoming tone or speech.
Line Terminal Mode Selections
Summary of mode selectable DIP switches:-
OFF - enableSW18-1 Timeout enable:
ON - disable (factory
setting)
OFF - fixed (factory setting)SW18-2 1 minute timeout selection:
ON - automatic
ON - enabledSW18-3 Internal Bell capacitor (disabled
when master socket is used)
OFF - disabled (factory
setting)
Loop Dial- A (factory
setting)
SW24-1 Loop Dial or DTMF Dial
DTMF- 1
APPROVED for connection to
telecommunication systems
specified in the instructions for
use subject to the conditions set
out in them
DAC Limited
Lomeshaye Business Village,
Turner Road. Nelson. BB9 7DR
Tel: +44(0) 1282 447000
Fax: +44 (0) 845 280 1915
DAC LIMITED
USER GUIDE
FOR RA711/1011, /1012 & /1013
VANDAL RESIST TELEPHONES
Part No: 552625
Issue 6
Vue de la page 0
1 2 3 4 5 6 7

Résumé du contenu

Page 1 - USER GUIDE

12 Document No 552625 Iss. 6 June 2005 1ELECTRICA

Page 2 - CONTENTS

2 11CONTENTSThis guide is in two parts. The first part is provided for users of thisinstrument and the second part is for the sole use of your approv

Page 3

2 111. Press 'ON', immediately followed by 'STORE'.2. Press particular Autodial key to be programmed, 'S0', 'S1&

Page 4 - ELECTRICAL INSTALLATION

10 3ELECTRICAL INSTALLATIONElectrical ConnectionsThe cables are passed through relevant conduit and connected (in thecase of directly wired situation

Page 5 - INSTALLATION

4 9APPROVED FACILITIESThis apparatus has been approved for use of the following facilities:-1 Loudspeaking (no handset) hands-free operation.2. Vis

Page 6

8 5INSTALLATIONThe following information is provided for use by the approved installer ortelephone network supplier only. The RA711 telephone can be

Page 7 - OPERATION - RA711/1011

6 7OPERATION - RA711/1011To make a callDepress the 'PRESS TO CALL' key, dialling tone will NOT be heard.Dialling takes place automatically,

Commentaires sur ces manuels

Pas de commentaire